Sika Latex R


About

Sika Latex R is a non-reemulsifiable bonding adhesive and fortifier. It can be used in patching, flash coats, stucco, and terrazzo.

Uses

  • Admixture used in cement based products to improve adhesion, achieve a denser surface, and improve overall performance.
  • As a bonding grout when mixed with sand and portland cement.

Specs

Instructions

Surface Prep

Applying Concrete/Mortar

  • Remove all deteriorated concrete, dirt, oil, grease, and all bond-inhibiting materials from surface.
  • Be sure repair is not less than 1/8 in. (3.2 mm) in depth.
  • Preparation work should be done by high pressure water blast, scabbler, or other appropriate mechanical means to obtain an aggregate-fractured surface with a minimum surface profile of 1/16 in. (1.6 mm).
  • Saturate surface with clean water. Substrate should be saturated surface dry (SSD) with no standing water during application.


Mixing

  • As admixture/mixing solution: With mixer running, add materials in the following order: SikaLatex R solution and then the cement based product. Replace the amount of water recommended by the product. Do not dilute with water.
  • As a bonding grout: With the mixer running, add in the following order. SikaLatex R solution, aggregate, cement. The ratio is 1 part cement, 2 parts sand, and a sufficient amount of undiluted SikaLatex R to produce a creamy paint consistency. Maximum 4 gal./ sack of cement (15L/sack of cement).
  • As a primer for acrylic coatings: No dilution is required. Use as is.


Application Method/Tools

  • Admixture: Immediately trowel SikaLatex R mortar or concrete mix into ares to be patched. Do not over-finish. As soon as the application is done, to prevent damage, cure with damp burlap and/or white pigmented polyethylene fil,. Curing should continue for 24 hours. Pre-testing is recommended when adding SikaLatex R to a specific mix design to assure the results required.
  • Bonding Grout: Brush grout into area to be resurfaced with stiff-bristled broom of scrub brush. Be sure entire surface and all edges are coated. Apply topping immediately over scrub coat before the bonding slurry dries.
  • Primer (for acrylic coatings only): Apply undiluted SikaLatex R to prepared concrete substrate using brushes, rollers, soft brooms, or spray. SikaLatex R must be tack-free (film formation) prior to coating. Estimated coverage on a CSP-3 prepared surface is 300 ft2/gal. (7 m2/l) SikaLatex R primer may be applied up to 24 hours ahead providing the area is kept dry and clean. Very porous concrete may require a second coat of SikaLatex R to seal the surface.


Limitations

  • Not resistant to UV rays unless painted, covered, or coated.
  • Will not adhere to polyethylene, teflon, silicone, oils and greases, mold release agents, and similar materials.
  • Do not expose to open flame or temperatures above 120°F (49°C). Excessive heat can cause shorter shelf life.
  • Not intended as a firestop.
  • Do not use where temperatures rise above 240°F (116°C).
  • As with all cement based materials, avoid contact with aluminum to prevent adverse chemical reaction and possible product failure. Insulate potential ares of contact by coating aluminum bars, rails, posts, etc.


See More

Sika Latex R

Quantity must be 1 or more
Regular price
$7.95
Sale price
$7.95

Improves the bond between old concrete and new concrete and, as a fortifier, improves strength, adhesion, and durability.

  • Concrete/mortar/grout exhibits improved adhesion to pre-pared substrates when containing Sika Latex R
  • Increased adhesive strength of mortar/concrete when used as a bonding grout
  • Increased resistance to freeze/thaw durability
  • Does not produce a vapor barrier

About

Sika Latex R is a non-reemulsifiable bonding adhesive and fortifier. It can be used in patching, flash coats, stucco, and terrazzo.

Uses

  • Admixture used in cement based products to improve adhesion, achieve a denser surface, and improve overall performance.
  • As a bonding grout when mixed with sand and portland cement.

Specs

Instructions

Surface Prep

Applying Concrete/Mortar

  • Remove all deteriorated concrete, dirt, oil, grease, and all bond-inhibiting materials from surface.
  • Be sure repair is not less than 1/8 in. (3.2 mm) in depth.
  • Preparation work should be done by high pressure water blast, scabbler, or other appropriate mechanical means to obtain an aggregate-fractured surface with a minimum surface profile of 1/16 in. (1.6 mm).
  • Saturate surface with clean water. Substrate should be saturated surface dry (SSD) with no standing water during application.


Mixing

  • As admixture/mixing solution: With mixer running, add materials in the following order: SikaLatex R solution and then the cement based product. Replace the amount of water recommended by the product. Do not dilute with water.
  • As a bonding grout: With the mixer running, add in the following order. SikaLatex R solution, aggregate, cement. The ratio is 1 part cement, 2 parts sand, and a sufficient amount of undiluted SikaLatex R to produce a creamy paint consistency. Maximum 4 gal./ sack of cement (15L/sack of cement).
  • As a primer for acrylic coatings: No dilution is required. Use as is.


Application Method/Tools

  • Admixture: Immediately trowel SikaLatex R mortar or concrete mix into ares to be patched. Do not over-finish. As soon as the application is done, to prevent damage, cure with damp burlap and/or white pigmented polyethylene fil,. Curing should continue for 24 hours. Pre-testing is recommended when adding SikaLatex R to a specific mix design to assure the results required.
  • Bonding Grout: Brush grout into area to be resurfaced with stiff-bristled broom of scrub brush. Be sure entire surface and all edges are coated. Apply topping immediately over scrub coat before the bonding slurry dries.
  • Primer (for acrylic coatings only): Apply undiluted SikaLatex R to prepared concrete substrate using brushes, rollers, soft brooms, or spray. SikaLatex R must be tack-free (film formation) prior to coating. Estimated coverage on a CSP-3 prepared surface is 300 ft2/gal. (7 m2/l) SikaLatex R primer may be applied up to 24 hours ahead providing the area is kept dry and clean. Very porous concrete may require a second coat of SikaLatex R to seal the surface.


Limitations

  • Not resistant to UV rays unless painted, covered, or coated.
  • Will not adhere to polyethylene, teflon, silicone, oils and greases, mold release agents, and similar materials.
  • Do not expose to open flame or temperatures above 120°F (49°C). Excessive heat can cause shorter shelf life.
  • Not intended as a firestop.
  • Do not use where temperatures rise above 240°F (116°C).
  • As with all cement based materials, avoid contact with aluminum to prevent adverse chemical reaction and possible product failure. Insulate potential ares of contact by coating aluminum bars, rails, posts, etc.