Order $24.50 or more to qualify for FREE Shipping on eligible items. (Contiguous 48)

Westcoat SC-42 – Clear Water-Based Acrylic Concrete Sealer – 5 Gallon

Westcoat SC-42 – Clear Water-Based Acrylic Concrete Sealer – 5 Gallon
Westcoat SC-42 – Clear Water-Based Acrylic Concrete Sealer – 5 Gallon
Westcoat SC-42 – Clear Water-Based Acrylic Concrete Sealer – 5 Gallon
Westcoat SC-42 – Clear Water-Based Acrylic Concrete Sealer – 5 Gallon
Westcoat SC-42 – Clear Water-Based Acrylic Concrete Sealer – 5 Gallon

About

SC-42 is designed to seal porous concrete, acrylic cement, brick, tile and some previously painted surfaces where a protective finish is desired. It is excellent for use as a general concrete sealer. SC-42 can be used on driveways, patios and walkways, as it fares well with tire traffic. SC-42 can be used in interior and exterior applications and can be used over Westcoat’s SC-10 Acrylic Topcoat to add gloss

Specs

  • Coverage: 
    Approx. 400 square feet per gallon on smooth surfaces 
    Approx. 250-350 square feet per gallon on rough surfaces
  • VOC Content: 
    <50 g/L
  • Mix Ratio: 
    SC-42 is ready to use straight from the container. SC-42 may be thinned with up to 25% water. Thinned material may require additional coats.
  • Dry Time: 
    Allow minimum 2 hours between coats and 6-8 hours before light foot traffic. Normal traffic may be permitted after 24 hours. Allow 72 hours before vehicle traffic. Allow 72 hours before placing heavy objects on the surface (use protective trays for pots and plants).
Tack Free over concrete @72°F
30 min.
Foot Traffic over concrete @72°F
1 hr.
Foot Traffic -sealed surface-  @72°F
1.5 hr.
Full Cure @ 6mil
72 hr.
Pencil Hardness
2H
Adhesion on concrete ASTM D3359
5
Reducer/Clean Up
Water

    Instructions

    Inspection

    Surfaces must be structurally sound and sloped for drainage. The surface must be dry and free of oil, grease, curing agents, dirt, dust or other foreign material that may prevent proper adhesion. The surface must be porous or rough enough to allow the product to soak in. 

    Moisture

    All concrete should be tested for moisture before applying a seamless coating. If moisture emissions exceed 5 lbs/1000 square feet (ASTM F1869) or if the relative humidity (RH) exceeds 75% (ASTM F2170), contact the manufacturer before application.

    Preparation

    For concrete, the surface should be at least 2500 psi and have cured for a minimum of 28 days. Prepare concrete to a profile equal to CSP 2-3. You may mechanically profile by scrubbing with a nylogrit brush on a floor machine (use TSP or degreaser if necessary) and follow by power-washing. Prior to starting work, test existing concrete slab for efflorescence, moisture and hydrostatic pressure. Vacuum surface entirely and ensure that any dust or contaminates are removed, as these will deter adhesion. 

    As a sealer for ALX™, MACoat™ or Texture-Crete®, apply directly over the textured surface. If texture has been left for more than 72 hours or it has become dirty, clean as needed prior to application of SC-42. Allow to fully dry. Note: The most common reason for coating failure is due to lack of preparation.

    Mixing

    Stir prior to use.

    Thinning

    SC-42 is ready to use straight from the container. SC-42 may be thinned with up to 25% water. Thinned material may require additional coats.

    Coverage

    Will vary depending on the surface. Up to 400 square feet per gallon on a smooth surface and between 250-350 square feet per gallon on a rough surface. Product performs best if applied in thin, even coats.

    Applying Product

    Before beginning any project, it is recommended that a mock-up be installed, to help indicate the overall look and finish and to determine compatibility to the substrate. 

    Neatly cut-in all edges with a brush and roll the center using a ½ to ¾ inch nap, good quality roller cover. Be sure to spread evenly in a “V” pattern rolling in both directions. Cutting slightly with water and applying thin coats will help avoid streaks in direct sun. SC-42 may also be applied with an airless or pump type sprayer. Apply in thin coats and avoid puddling. 

    Use over SC-10 by applying a very thin coat using the above methods. CA-30 Safe-Grip additive may be used to help gain traction.

    Dry Time

    Allow minimum 2 hours between coats and 6-8 hours before light foot traffic. Normal traffic may be permitted after 24 hours. Allow 72 hours before vehicle traffic. Allow 72 hours before placing heavy objects on the surface (use protective trays for pots and plants).

    Clean Up

    Uncured material should be removed with soap and warm water. Cured material should be removed mechanically or with an environmentally-safe solvent.

    Limitations

    • This product is designed for professional use only
    • Do not apply at temperatures below 50°F or above 90°F. Hot or cold weather may affect dry times
    • Be sure to do adequate surface preparation
    • Rain will wash away uncured acrylic products. If inclement weather threatens, cover deck to protect new application 
    • Surface will become more slippery with this sealer
    • Skid resistant additives are available
    • Apply only over compatible water based acrylics and bare, porous surfaces such as concrete and pavers
    • Do not apply over glazed tile or hard fired bricks
    • Do not apply over natural stone which is too dense and smooth 
    • Not recommended over Acid Stain without test area
    • Do a test area before you begin
    • Do not allow any Westcoat products to freeze
    Full instructions See More

    Westcoat SC-42 – Clear Water-Based Acrylic Concrete Sealer – 5 Gallon

    Quantity must be 1 or more
    Regular price
    $169.95
    Sale price
    $169.95
    SC-42 is a one part, water-based, clear acrylic concrete sealer. It is high quality, easy to use and cost effective. SC-42 typically will not darken the substrate, like a solvent-based acrylic and will provide a more subdued finish.
    • Transparent, semi-gloss finish
    • Designed to seal porous concrete, pavers, acrylic cement, non-hard-fired brick, and un-glazed tile; Do not apply over natural stone which is too dense and smooth
    • SC-42 can be used on driveways, patios and walkways, as it fares well with tire traffic
    • Fast drying and easy to use; Apply with a sprayer or roller
    • Water-based; Low odor
    • UV resistant; Clear; Non-yellowing
    • Cost effective with excellent adhesion and very durable

    About

    SC-42 is designed to seal porous concrete, acrylic cement, brick, tile and some previously painted surfaces where a protective finish is desired. It is excellent for use as a general concrete sealer. SC-42 can be used on driveways, patios and walkways, as it fares well with tire traffic. SC-42 can be used in interior and exterior applications and can be used over Westcoat’s SC-10 Acrylic Topcoat to add gloss

    Specs

    • Coverage: 
      Approx. 400 square feet per gallon on smooth surfaces 
      Approx. 250-350 square feet per gallon on rough surfaces
    • VOC Content: 
      <50 g/L
    • Mix Ratio: 
      SC-42 is ready to use straight from the container. SC-42 may be thinned with up to 25% water. Thinned material may require additional coats.
    • Dry Time: 
      Allow minimum 2 hours between coats and 6-8 hours before light foot traffic. Normal traffic may be permitted after 24 hours. Allow 72 hours before vehicle traffic. Allow 72 hours before placing heavy objects on the surface (use protective trays for pots and plants).
    Tack Free over concrete @72°F
    30 min.
    Foot Traffic over concrete @72°F
    1 hr.
    Foot Traffic -sealed surface-  @72°F
    1.5 hr.
    Full Cure @ 6mil
    72 hr.
    Pencil Hardness
    2H
    Adhesion on concrete ASTM D3359
    5
    Reducer/Clean Up
    Water

      Instructions

      Inspection

      Surfaces must be structurally sound and sloped for drainage. The surface must be dry and free of oil, grease, curing agents, dirt, dust or other foreign material that may prevent proper adhesion. The surface must be porous or rough enough to allow the product to soak in. 

      Moisture

      All concrete should be tested for moisture before applying a seamless coating. If moisture emissions exceed 5 lbs/1000 square feet (ASTM F1869) or if the relative humidity (RH) exceeds 75% (ASTM F2170), contact the manufacturer before application.

      Preparation

      For concrete, the surface should be at least 2500 psi and have cured for a minimum of 28 days. Prepare concrete to a profile equal to CSP 2-3. You may mechanically profile by scrubbing with a nylogrit brush on a floor machine (use TSP or degreaser if necessary) and follow by power-washing. Prior to starting work, test existing concrete slab for efflorescence, moisture and hydrostatic pressure. Vacuum surface entirely and ensure that any dust or contaminates are removed, as these will deter adhesion. 

      As a sealer for ALX™, MACoat™ or Texture-Crete®, apply directly over the textured surface. If texture has been left for more than 72 hours or it has become dirty, clean as needed prior to application of SC-42. Allow to fully dry. Note: The most common reason for coating failure is due to lack of preparation.

      Mixing

      Stir prior to use.

      Thinning

      SC-42 is ready to use straight from the container. SC-42 may be thinned with up to 25% water. Thinned material may require additional coats.

      Coverage

      Will vary depending on the surface. Up to 400 square feet per gallon on a smooth surface and between 250-350 square feet per gallon on a rough surface. Product performs best if applied in thin, even coats.

      Applying Product

      Before beginning any project, it is recommended that a mock-up be installed, to help indicate the overall look and finish and to determine compatibility to the substrate. 

      Neatly cut-in all edges with a brush and roll the center using a ½ to ¾ inch nap, good quality roller cover. Be sure to spread evenly in a “V” pattern rolling in both directions. Cutting slightly with water and applying thin coats will help avoid streaks in direct sun. SC-42 may also be applied with an airless or pump type sprayer. Apply in thin coats and avoid puddling. 

      Use over SC-10 by applying a very thin coat using the above methods. CA-30 Safe-Grip additive may be used to help gain traction.

      Dry Time

      Allow minimum 2 hours between coats and 6-8 hours before light foot traffic. Normal traffic may be permitted after 24 hours. Allow 72 hours before vehicle traffic. Allow 72 hours before placing heavy objects on the surface (use protective trays for pots and plants).

      Clean Up

      Uncured material should be removed with soap and warm water. Cured material should be removed mechanically or with an environmentally-safe solvent.

      Limitations

      • This product is designed for professional use only
      • Do not apply at temperatures below 50°F or above 90°F. Hot or cold weather may affect dry times
      • Be sure to do adequate surface preparation
      • Rain will wash away uncured acrylic products. If inclement weather threatens, cover deck to protect new application 
      • Surface will become more slippery with this sealer
      • Skid resistant additives are available
      • Apply only over compatible water based acrylics and bare, porous surfaces such as concrete and pavers
      • Do not apply over glazed tile or hard fired bricks
      • Do not apply over natural stone which is too dense and smooth 
      • Not recommended over Acid Stain without test area
      • Do a test area before you begin
      • Do not allow any Westcoat products to freeze
      Full instructions